UL 94 Flame Ratings for Tape and Film: What V0, VTM-0 and HB Actually Mean

Nov 17, 2026

Leave a message

Emily Zheng
Emily Zheng
Emily Zheng is a product developer at STK Tape. She has been involved in the R & D process of adhesive tapes for more than 8 years. Her innovative ideas and in - depth knowledge of materials have contributed significantly to the company's product line expansion in sectors like LED lighting and medical.
 

UL 94 Flame Ratings for Tape and Film: What V-0, VTM-0 and HB Actually Mean

 

UL 94 is the most quoted compliance mark in the world, and one of the most misunderstood. A datasheet that says "UL 94 V-0" tells you something specific and narrow: it tells you how a specimen of that material behaved in a small flame test held in a particular orientation. It does not tell you that the material will survive a real fire, it does not tell you the material's temperature rating, and it does not tell you that the rating applies at any thickness other than the one tested.

This guide sets out the five UL 94 classifications, explains why the VTM series exists and when it is the correct mark to specify, and separates the two independent properties that buyers most often confuse: flame behaviour and heat resistance. It then works through the flame records we hold for Formex, Nomex and Sabic Lexan materials, and maps application requirements to the grade each one needs.

 

The UL 94 Rating System: HB, V-2, V-1, V-0 and VTM

UL 94 classifies materials by how they behave when a flame is applied to a specimen held in a defined orientation. The orientation is what separates the HB family from the V family, and the flammability criteria separate the grades within each family.

 

HB is the horizontal burning classification. The specimen lies flat and the flame is applied to one end, so the material is allowed to burn along its length rather than downward. This is the most permissive classification in UL 94 and it exists because many general-purpose plastics burn steadily rather than dangerously. A material rated only HB has not demonstrated any self-extinguishing behaviour.

 

V-2, V-1 and V-0 are the vertical burning classifications. The specimen is held vertically, so burning proceeds upward against gravity - the direction in which a material in a cabinet, a vehicle or an enclosure would actually burn. The three grades differ in how long the material continues to burn after the flame is removed and in whether flaming drips are produced.

 

VTM is the vertical thin material classification. It is the film-specific counterpart to the V series, developed for materials too thin or too flexible to be classified by the standard vertical specimen geometry. It is not a sixth point on the same scale: it is a separate test family with its own specimen and its own criteria.

 

UL 94 grade

Test orientation

What the classification means

Where you see it specified

HB

Horizontal burning

Burns at a limited rate along its length; no self-extinguishing performance demonstrated

General-purpose plastics, housings and enclosures with no active flame risk

V-2

Vertical burning

Continues burning after flame removal within the V-2 limit; flaming drips permitted

Thin moulded parts where a small amount of dripping is tolerable

V-1

Vertical burning

Burning time after flame removal within the V-1 limit; no flaming drips

Enclosures, appliance housings, equipment covers

V-0

Vertical burning

Self-extinguishes within the shortest vertical limit; no flaming drips; glowing combustion limited

Electrical enclosures, transformer and motor insulation, safety-critical housings

VTM-0

Vertical thin material

The V-0-level classification applied to thin, flexible material under the thin-material test method

Films, tapes, laminates and flexible materials that are too thin for V-series testing

Two features of the table are worth underlining. First, every rating in UL 94 is attached to a material at a tested thickness. A 10 mil grade does not transfer to a 2 mil version of the same material, because thin specimens burn differently and are easier to ignite. Second, the ratings describe a laboratory specimen, not an assembly performance - an enclosure rated V-0 can still contain a cable tie or a label that is not.

 

V-0 vs VTM-0: The Difference That Matters for Thin Films

This is the question that causes the most confusion in tape specification, because both marks look authoritative and both appear on film datasheets, and only one of them is the correct reference for a thin material.

 

V-0 refers to the standard vertical burning test. It is defined for a rigid specimen of a given geometry and thickness. A 10 mil polycarbonate film sheet tested to V-0 has passed the vertical burning test at that thickness, using the standard specimen and mounting.

 

VTM-0 refers to the vertical thin material test. Where a material is a film, a tape or a flexible laminate that cannot be mounted and burned as a rigid vertical specimen, the VTM method provides the classification. It is a different procedure with its own specimen handling, and VTM-0 is the rating that corresponds to the V-0 level of severity.

 

So the answer for a buyer is straightforward: for a thin film or a tape, ask for VTM-0. A datasheet that offers only a V-0 rating for a 2 mil or 5 mil material is either referring to a different test, referring to a thicker version of the same material, or has made an error. None of those is a specification you should accept for a thin part.

The practical trap is that VTM ratings are frequently listed without the specification number, the test method reference, or the tested thickness. Our own position is stated on this directly: "Official flame compliance records for Formex, Nomex, and Sabic Lexan materials (UL 94 V-0 / VTM-0)" - both families appear, and the record states which applies to which material.

Question

UL 94 V-0

UL 94 VTM-0

Test family

Vertical burning on the standard rigid specimen

Vertical thin material test method

Typical material form

Moulded or extruded rigid parts, sheets at tested thickness

Films, tapes, flexible laminates, thin-supported material

What it certifies

Self-extinguishing behaviour with no flaming drips, at the tested thickness

The equivalent severity level applied to a thin or flexible specimen

Thickness dependency

Applies only to the tested thickness

Applies only to the tested thickness and specimen construction

Which to specify for a die-cut tape part

Only if the tape is thick enough to be tested as a rigid specimen

Yes - the applicable family for film and tape

 

What a V-0 Rating Does Not Prove

A flame rating and a temperature rating are two independent properties, measured by two different tests, answering two different questions. Conflating them is the single most consequential misunderstanding in this area, because it produces a part that passes the paperwork and fails in service.

 

Flame rating answers: how does the material behave when it is ignited? Continuous temperature rating answers: how hot can the material be before it degrades? Nothing in a UL 94 flame test measures temperature resistance. The flame in the test is a few hundred degrees for a few seconds - it never establishes what the material does at 150°C over a year.

The clearest demonstration is in our own material comparison table below. Sabic Lexan FR700 carries a UL 94 V-0 rating at 130°C continuous. DuPont Nomex 410 also carries a UL 94 V-0 rating, but at Class H (220°C). Both are flame-rated V-0; one is a polycarbonate film, the other a synthetic aramid paper, and their temperature capabilities differ by ninety degrees. ITW Formex GK-10 is UL 94 V-0 at 115°C continuous, which means a flame rating better than the temperature capability of many unrated engineering plastics.

There is a third thing a V-0 rating does not prove, and it is the one that shows up in audits: a UL 94 rating applies to the base material. It does not automatically transfer to the converted part. A die-cut part, a laminated part or a part with an adhesive applied has a different construction than the tested specimen, and it is the finished construction that is in your assembly.

It is also worth being precise about what flame retardancy itself means. Flame retardant is a description of behaviour - the material resists ignition or self-extinguishes - not a certification mark, and not a guarantee of safety. A V-0 rating does not imply low smoke or halogen-free chemistry.

 

Reading Flame Records for Formex, Nomex and Lexan

 

When you ask a converter for flame compliance records, the useful answer names the materials, the ratings and the basis. Our own record is stated in one line: "Official flame compliance records for Formex, Nomex, and Sabic Lexan materials (UL 94 V-0 / VTM-0)." Three material families, two rating families, one record.

Reading that record properly means asking three follow-up questions. Which rating applies to which material - Formex GK-10 is a flame-retardant polypropylene rated UL 94 V-0; Lexan FR700 is a polycarbonate film rated UL 94 V-0; the VTM-0 classification applies to the thin-supported grades in these families. At what thickness - each of these materials is specified at a thickness in our published specification: 10 mil (0.25 mm) for both Formex GK-10 and Lexan FR700, and 5 mil (0.13 mm) for Nomex 410. And under which test method - V-0 for the rigid specimens, VTM-0 for the thin-material ones.

None of those three questions is answered by the rating alone, which is why a bare "UL 94 V-0" on a quotation is not enough to write a purchasing requirement against.

 

Flame Class by Material Family: A Real Comparison

 

The table below reproduces our published brand and material comparison, with the temperature rating and flame class on the same row as the material construction. This is the reference we use internally, and it is where the flame-versus-temperature distinction becomes concrete: read down the temperature column and the same V-0 rating appears against 115°C, 130°C and 220°C.

 

Brand and material comparison: temperature rating and flame class shown on the same row

Brand / Material

Featured SKU

Material / Backing

Thickness

Temp Rating / Flame Class

Primary Converting Options

Tesa Tape

Tesa 4965

Double-Coated PET Film

8.1 mil (0.20 mm)

100°C Cont. / 200°C Peak

Slitting, Log Rolls, Precision Die-Cut

Nitto Tape

Nitto 500

Double-Coated Tissue

6.3 mil (0.16 mm)

80°C Cont. / 120°C Peak

Slitting, Spooled Rolls, Die-Cut

Scapa Tape

Scapa 2702 Series

Premium Soft PVC Tape

5.1 mil (0.13 mm)

90°C Cont.

Harness Slitting, Custom Log Rolls

Saint-Gobain Tape

CHR PTFE Series

PTFE Film / Silicone Adhesive

3.5 mil (0.09 mm)

260°C Cont.

Precision Slitting, Die-Cut Parts

Sekisui Tape

Sekisui Voltek Foam

Cross-linked Polyolefin Foam

Custom Calipers

80°C Cont.

Lamination, Cushion Die-Cutting

Kikusui Tape

Kikusui Masking Series

Saturated Crepe Paper

5.5 mil (0.14 mm)

150°C Peak (Paint Bake)

Slitting, Custom Precision Widths

Sabic Lexan

Lexan FR700

Polycarbonate Film

10 mil (0.25 mm)

UL 94 V-0 / 130°C Cont.

Score-Folding, PSA Lamination, Die-Cut

ITW Formex

Formex GK-10

Flame-Retardant Polypropylene

10 mil (0.25 mm)

UL 94 V-0 / 115°C Cont.

Score-Folding, PSA Lamination, Die-Cut

DuPont Nomex

Nomex 410

Synthetic Aramid Paper

5 mil (0.13 mm)

Class H (220°C) / UL 94 V-0

PSA Lamination, Precision Slitting, Die-Cut

Rogers PORON

PORON 4701 Series

Microcellular Polyurethane Foam

0.5 mm - 12.7 mm

90°C Cont. / 121°C Peak

Custom Die-Cut, PSA Lamination, Sheets

 

Read the temperature column carefully alongside the flame class column. ITW Formex GK-10 is a flame-retardant polypropylene at 10 mil (0.25 mm), UL 94 V-0, rated to 115°C continuous. Sabic Lexan FR700 is a polycarbonate film at the same 10 mil (0.25 mm), also UL 94 V-0, rated to 130°C continuous - a higher temperature ceiling with the same flame classification. DuPont Nomex 410 is a synthetic aramid paper at 5 mil (0.13 mm), rated Class H (220°C) and UL 94 V-0.

 

The rest of the table is the control group, and it is where a buyer learns that a flame class and a temperature limit are separately specified properties. Saint-Gobain CHR PTFE Series runs at 260°C continuous with no flame class shown in the same cell. Tesa 4965 is a double-coated PET film at 100°C continuous and 200°C peak. Rogers PORON 4701 is a microcellular polyurethane foam from 0.5 mm to 12.7 mm thick, at 90°C continuous and 121°C peak. A polyurethane foam without a flame class and a polytetrafluoroethylene film at 260°C both sit in the same catalogue as the V-0 materials - and that is exactly the point.

One practical note on thickness: Sekisui Voltek Foam is specified as "Custom Calipers", a reminder that a foam part's flame behaviour depends on the density and caliper of the grade supplied. For a die-cut foam part, the rating that matters is the rating for the caliper you actually receive.

 

Which Flame Rating Your Application Actually Requires

Buyers frequently specify the highest grade they can find rather than the grade the application needs. That has two costs: it can make a part uneconomical for no benefit, and it can create false confidence, because a higher flame class in a non-critical position does not make the assembly safer.

The table below maps common industrial applications to the classification that is normally appropriate, and states the reasoning. It is a starting point for the engineering conversation, not a substitute for your own risk assessment.

Application

Grade normally required

Why that grade and not a higher one

Electrical and electronic enclosures, motor and transformer insulation

UL 94 V-0 on the insulating material

Enclosure fires burn upward, so the rating must be tested vertically; the material must not produce flaming drips onto live parts

Thin film, tape and laminate used as an insulating or spacing layer

UL 94 VTM-0

A thin or flexible material cannot be mounted as a rigid vertical specimen, so the thin-material test is the applicable one

Appliance housings and equipment covers with an internal fire risk

UL 94 V-1

Vertical burning is required, but flaming drips from a modest mass of material are tolerated where the enclosure contains them

Non-critical enclosures, tooling, and internal covers away from a heat source

UL 94 HB

Horizontal burning is sufficient where the material is not part of the fire load path and no vertical flame spread risk exists

Materials required to hold a raised temperature in service alongside a flame requirement

Both specified independently

A flame rating and a temperature rating come from two different tests, so they need two separate requirements

 

The last row is the one we would underline. When your application needs both a flame class and a temperature capability, write them as two separate lines in the specification, each with its own test method and its own limit. A single combined requirement - "V-0 and 180°C", for example - invites a supplier to offer whichever material satisfies one of the two, and leaves the other undefined.

 

 

Why Buyers Choose STK Tape for This Application

STK Tape is a converter and die-cutting manufacturer for industrial adhesive tapes, based in Quanzhou, Fujian, China. We work with well-known adhesive tape brands including 3M, tesa and Nitto. We source branded materials through our supply channels and convert them to your specifications - slitting, kiss-cutting, rotary and flatbed die-cutting, score-folding and PSA lamination.

 

A note on what we are: STK Tape is a converter, not a tape coater and not a brand owner. We buy branded material, convert it to your dimensions and die-cut it to your drawing. Every quotation we issue states the origin, the brand status and the TDS parameters of the material, so you always know what you are buying.

 

STK Tape was established in 1998 and has been engaged in the adhesive tape industry for more than two decades. The company owns four production bases covering over 60,000 square meters, with clean rooms, high-precision coating lines, slitting machines and die-cutting facilities. We are certified to ISO 9001 and ISO 14001, and our products comply with REACH, RoHS and UL requirements. We export to over 80 countries, serving both multinational manufacturers and regional distributors across electronics, automotive, medical, energy, aerospace, home appliances, textile and industrial manufacturing.

Our factory integrates R&D, production, testing and customization, supporting large-scale OEM/ODM projects with fast delivery and flexible capacity.

 

Key Takeaways

UL 94 grades describe laboratory flame behaviour, not fire safety and not heat resistance. A V-0 rating does not mean a material survives a real fire.

HB is horizontal burning; V-2, V-1 and V-0 are vertical burning with progressively stricter limits; VTM is the separate thin-material family for films and flexible parts.

For a die-cut tape part, ask for VTM-0. V-0 applies to rigid specimens tested at the stated thickness and does not transfer to a thin version of the same material.

Every UL 94 rating is thickness-specific. A rating at 10 mil does not transfer to a 2 mil version of the same material.

Flame rating and continuous temperature rating are independent. Lexan FR700 is UL 94 V-0 at 130°C; Nomex 410 is UL 94 V-0 at Class H (220°C); Formex GK-10 is UL 94 V-0 at 115°C.

A rating applies to the base material, not automatically to the converted part. Always ask which rating, which thickness, which test method - and require both a flame class and a temperature limit as two separate lines.

 

Request a Quotation

Send us your part number, drawing or application description. STK Tape responds to technical enquiries and feasibility requests within 24 hours - including a material recommendation, a tolerance assessment and a quotation.

Email Info@stktape.com

Phone / WhatsApp +86 180 5985 0476

Working hours Quote and feasibility response within 24 hours

Frequently Asked Questions

 

Frequently Asked Questions

What is the difference between UL 94 V-0 and VTM-0?

They are different test families, not two grades on one scale. V-0 is the vertical burning classification defined for a standard rigid specimen. VTM-0 is the vertical thin material classification, developed with its own specimen handling for films, tapes and flexible laminates that cannot be tested as a rigid vertical specimen, and it corresponds to the V-0 level of severity. For a thin film or a die-cut tape part, VTM-0 is the applicable rating; a V-0 rating quoted for a 2 mil material is either referring to a different test or to a thicker version of the same material.

 

Is UL 94 V-0 the same as flame retardant?

No - one is a classification, the other is a description. Flame retardant describes a behaviour: the material resists ignition or self-extinguishes. UL 94 V-0 is a classification assigned under a specific test method, at a specific thickness, for a specific specimen. Flame retardancy also does not imply low smoke, low toxicity or halogen-free chemistry, and a V-0 material in an enclosure can still contribute to a fire through other components in that enclosure.

 

Which materials achieve VTM-0?

VTM-0 is achieved by thin, flexible materials tested under the vertical thin material method - films, tapes and laminates that cannot be mounted as a rigid vertical specimen. In our published range the thin-supported grades within the Formex, Nomex and Sabic Lexan families carry VTM-0 classifications, alongside V-0 on the rigid specimens. Our flame compliance record states it directly: official flame compliance records for Formex, Nomex, and Sabic Lexan materials (UL 94 V-0 / VTM-0). Ask for the record and confirm the tested thickness.

 

Does a V-0 rating mean the tape is heat resistant?

No, and this is the misunderstanding with the largest practical consequence. A flame rating and a continuous temperature rating come from two different tests answering two different questions, and a flame test never establishes temperature resistance. Our own material comparison makes the point: Lexan FR700 is UL 94 V-0 at 130°C continuous, Nomex 410 is UL 94 V-0 at Class H (220°C), and Formex GK-10 is UL 94 V-0 at 115°C continuous. Specify the flame class and the temperature limit as two separate lines in your specification.

 

What is UL 94 HB used for?

HB is the horizontal burning classification, and it is the most permissive grade in UL 94. The specimen lies flat and the flame is applied to one end, so the material is allowed to burn along its length rather than upward against gravity. It is used for general-purpose plastics in housings, tooling and covers where there is no meaningful vertical flame spread risk and the material is not part of the fire load path. A material carrying only an HB rating has demonstrated no self-extinguishing behaviour, so it is not a substitute for V-0 in an enclosure.

Send Inquiry
Looking for the Right Adhesive Tape Solution?
Tell us about your materials, specifications and application requirements. Our team will help identify the right solution for your project.